BIG(basic type), IG(normal type), SIG(superior type)
Precision
3 years
pc, PC
1pcs/box,5pcs/box,20pcs/box
300000 Piece/Pieces per Month
High Quality Cheap China Disposable circumcision stapler
CE
3 years
3 years
Disposable Surgery Instruments
10pcs
Yes
Machinery
Online technical support
Availability: | |
---|---|
Disposable laparoscopic puncture apparatus introduction
Product Name | Sterile Trocar For Single Use |
Model | S(basic type), M(normal type),L(superior type) |
Size | dia 5mm 10mm 12mm 15mm, length 75cm 100cm 150cm |
Packing info | 1pcs/box,5pcs/box, 20pcs/box |
Patent | first entry to build safe pneumoperitoneum |
Non-cutter expansion type puncture
Minimally invasive puncture conical head without fascial suture.
conical head, to open the tissue through the expansion,so as to prevent abdominal wall and vascular from being injured.
Blunt-head non-cutter design, to protect the organs fully, so as to prevent any injury.
Good seal design and maintain intraoperative pneumoperitoneum.
Slip thread design of the fixed tooth pattern so as to ensure stronger abdominal wall fixation force.
Three-way valves, to release the air quickly, thus protecting the medical and health care personnel from being polluted.
Under the support of a 12mm puncture device and the guide of a 30 degree mirror.
Universal conversion cap,the same conversion cap to let the 5-2mm device pass without need for replacing the conversion cap during the surgery.
Laparoscopic surgery is a surgical technique in which short, narrow tubes (trochars) are inserted into the abdomen through small (less than one centimeter) incisions. Through these trochars, long, narrow instruments are inserted. The surgeon uses these instruments to manipulate, cut, and sew tissue.
Model Number | Puncture Core Diameter(D) | Puncture Sleeve Length(L) | Puncture Casing Diameter(d) |
PC5S | 5.8±0.8 | 77±2 | 6.4±0.2 |
PC5M | 102±2 | ||
PC5L | 152±2 | ||
PC10S | 10.8±0.8 | 77±2 | 11.4±0.2 |
PC10M | 102±2 | ||
PC10L | 152±2 | ||
PC12S | 12.8±0.8 | 77±2 | 13.4±0.2 |
PC12M | 102±2 | ||
PC12L | 152±2 | ||
PC15S | 15.8±0.8 | 77±2 | 16.4±0.2 |
PC15M | 102±2 | ||
PC15L | 152±2 |
Clinically, Disposable laparoscopic puncture apparatus is used for laparoscopic surgery to establish a surgical channel.
The main structure of this product: The surgical trocar is mainly composed of a cone, connecting tube (lengthened type), sleeve, an air injection switch, a locking fixed cover, a positioning guide cover, a conversion cap sealing cap, and a conversion cap, injection valve, sealing cap and choke valve.
Package specifications | Group into |
PC5/5M | Contains 2 5M puncture sleeves; 1 5M puncture core. |
PC5/10M | Contains 1 5M bud thorn casing, 1 10M puncture casing; 1 5M bud thorn core, 1 10M bud thorn core. |
PC5/12M | Contains 1 5M bud thorn sleeve, 1 12M puncture sleeve; 1 5M bud thorn core, 1 12M bud thorn core. |
PC5/5/10M | Contains 2 5M puncture sleeves, 1 10M puncture sleeve; 1 5M bud thorn core, 1 10M bud thorn core. |
PC5/5/12M | Contains 2 5M puncture sleeves, 1 12M puncture sleeve; 1 5M bud thorn core, 1 12M bud thorn core. |
PC5/10/10M | Contains 1 5M puncture cannula, 2 10M puncture cannula; 1 5M bud thorn core, 1 10M bud thorn core. |
PC5/12/12M | Contains 1 5M puncture cannula, 2 12M puncture cannula; 1 5M bud thorn core, 1 12M bud thorn core. |
PC5/10/12M | Contains 1 5M puncture cannula, 1 10M puncture cannula, 1 12M puncture cannula; 1 5M bud puncture core, 1 10M puncture core, 1 12M puncture core. |
PC5/5/10/10M | Contains 2 5M puncture sleeves, 2 10M puncture sleeves; 1 5M bud thorn core, 1 10M bud thorn core. |
PC5/5/12/12M | Contains 2 5M puncture sleeves, 2 12M puncture sleeves; 1 5M bud thorn core, 1 12M bud thorn core. |
PC5/5/10/12M | Contains 2 5M puncture cannula, 1 10M puncture cannula, 1 12M puncture cannula; 1 5M bud puncture core, 1 10M puncture core, 1 12M puncture core. |
The Single-Use Laparoscopic Bladeless Trocar is designed to be used in the Minimally Invasive Surgery (MIS) to puncture the abdominal wall for creating the working tunnels and maintain the pneumoperitoneum during the surgeries.
The disposable trocar in laparoscopic surgery is not intended to be used when endoscopic techniques generally are the contraindications.
Quantity(Pieces) | 1 - 10 | 11 - 50 | 51 - 100 | >100 |
Est. Time(days) | 5 | 10 | 15 | To be negotiated |
Use aseptic technique to take out the instrument from the package. In order to avoid damage to the instrument, the instrument must not be thrown into the sterile area.
When packaging, the puncture core of the puncture device and the puncture sleeve are not installed together. When assembling, the puncture core is inserted into the puncture sleeve until the two are firmly locked together. Before use, close the choke valve. When the choke valve is perpendicular to the gas injection port, the choke valve is in the closed position.
Using standard surgical techniques, make a skin incision that is enough to introduce the trocar. An incision that is too small may cause too much resistance during insertion and requires more force to insert, which may cause uncontrollable insertion.
Introduce the trocar through the skin incision, rotate the trocar in the range of 30° to 90° during introduction, and press the trocar down gently and rhythmically during introduction.
After the puncture device enters the abdominal cavity or thoracic cavity, press the button button of the puncture core to remove the puncture core, leaving the puncture sleeve in its original position. When the puncture core is withdrawn, the inner sealing layer of the puncture sleeve will automatically close. When there is no instrument in the puncture cannula, the sealing system remains inflated.
When inflating, you can connect the trachea to the gas injection valve on the trocar sleeve and open the choke valve. When there is no instrument in the puncture sleeve, the sealing system remains inflated.
When taking out the specimen during the operation, press the middle body lock button, and then lift the sealing cap to remove the sealing cap. After taking out the specimen, put the sealing cap back on the trocar and hear a "pop" from the middle body lock, indicating that the sealing cap has been installed in place.
After the operation is completed, remove the inflation tube. Open the choke valve and quickly release the gas in the abdominal cavity.
The design of trocar surgical instrument avoids the risk of injury to internal organs, fascia suture is not required.
Excellent leakage prevention.
Wear-resisitance to support frequent instrument exchanges.
Perfect wrapping instrument rod to provide better prevention of leakage.
Three-layers structure and special materials of the medical trocar ensure gas proofness performance.
Accommodate instruments from 5mm to 12mm, no need converter.
The thread design of our disposable trocar strengthens abdominal wall fixation, no need suture fixation.
1. Q: Are you disposable laparoscopic puncture apparatus manufacturer or trading company?
A: Precision Medical is disposable laparoscopic puncture apparatus manufacturer
2. Q: Can I order 1 or 2 pcs as the same price for the distributors?
A: Yes
3. Q: What is the delivery time?
A: 7 days for Storage.
4. Q:Can you print our logo on the products?
A:Yes
5. Q: What’s your warranty and after service policy?
A:3 Years
6. Q: What is the MOQ?
A:1 piece
Disposable Model-trocar Surgical Laparoscopic
Sterile Trocar For Single Use
Disposable Laparoscopic Puncturefactory Direct Sell Laparoscopic Device
Disposable Surgical Stapler Reloads
Ce Disposable Trocar Cannula Trocar Kit Bladeless Trocar
Disposable Laparoscopic Trocar